COMMON FEATURES
bullet High accuracy ±0.4°C J T/C and ±0.3°C 4W PT385 RTD all errors included
bullet 10 T/C types and 8 RTD types including PT 385 (1000 ohm) and cu (10 ohm)
bullet Direct keyboard entry or scroll control of output
bullet Nema 4 rated case, rugged design
bullet RTD simulation works with all pulsed (smart) transmitters
bullet YSI 400 series thermistor range for medical applications
bullet Standard mini-plug or banana jack connections for T/C
bullet Store up to nine setpoints for each output function
bullet RS232 Interface
The Martel PTC-8001 Precision Temperature Calibrator is an ideal device to handle all of your temperature calibration needs in a truly rugged, low cost package. It combines virtually all widely used thermocouples and RTDs in one device—you’ll never have to worry about finding a temperature device you can’t calibrate.

This is especially true when calibrating “smart” or pulsed RTD transmitters where many other calibra-tors fail to work or operate at reduced accuracy specs. The PTC-8001 handles those applications with ease.

Each Unit Includes: Test leads, carrying case, 4 AA alkaline batteries, NIST Certificate, and instruction manual.

Note: For T/C please order T/C cable kit.
General Specifications:
T/C Ranges: J, K, T, E, R, S, N, B, L, U including – 10 to 70 mV range
RTD Ranges: Pt 385 (100, 200, 500, 1000 ohms)
Pt 392, JIS, Ni 120, CU10, YSI 400
Ohms Ranges: 0 to 400.00 and 400.0 to 4000.0
Accuracy: T/C Type J: ±.3°C ±10
V (±0.6°C total error)
RTD PT100: ±.1°C ±.075 (±0.3°C total error)
Ohms (400): ±0.1
Ohms (4000): ±1.0
RTD IEX-range: 0.01 mA to 3 mA
RTD Frequency Response:
10 mS – works with all pulsed XMTR’s
Oper. Temp: -10°C to 50°C
Storage Temp: -20°C to 60°C
Power Supply: 4 AA Alkaline Cells, 30 hours typical operating time
Size: 7.5" x 4" x 1.5"

 

Range: Min Max Accuracy
Ohms Read 4w (low): 0.00 400.00 0.1 ohm
Ohms Read 4w (high): 400.0
1500.0
1500.0
4000.0
0.5 ohm
1.0 ohm
Ohms Ranges:
Range: Min Max Excitation Current Accuracy
Ohms Source (low): 5.00
5.00
400.00
400.00
0.1 to 0.5 mA
0.5 to 3 mA
0.15 ohm
0.1 ohm
Ohms Source (high): 400.0
1500.0
1500.0
4000.0
0.05 to 0.8 mA
0.05 to 0.4 mA
0.5 ohm
1.0 ohm

 

RTD Read and Source
Range: Min Max Accuracy
Ni120 (672) -80.0 260.0 0.2°C
Pt100 (385) -200.0 800.0 0.33°C
Pt100(3926) -200.0 630.0 0.3°C
Pt100(3916) -200.0 630.0 0.3°C
Pt200(385) -200.0
100.0
630.0 0.8°C
Pt500(385) -200.0
500.0
500.0
630.0
0.3°C
0.4°C
Pt1000(385) -200.0
100.0
100.0
630.0
0.2°C
0.3°C
Cu10 -100.0 250.0 2.2°C
YSI400 15.00 50.00 0.05°C

 

Thermocouple Read and Source (All errors included)
Range: Min Max Accuracy
J Thermocouple -200.0
0.0
0.0
1200.0
0.6°C
0.4°C
K Thermocouple -200.0
0.0
0.0
1370.0
0.8°C
0.5°C
T Thermocouple -200.0
0.0
0.0
400.0
0.8°C
0.5°C
E Thermocouple -200.0
0.0
0.0
950.0
0.5°C
0.4°C
R Thermocouple -20
0
50.0
0.0
500
1750
2.4°C
1.7°C
1.3°C

 

Range: Min. Max. Accuracy
S Thermocouple -20
0
500
-20
0
1750
2.4°C
1.7°C
1.4°C
B Thermocouple 600
8000
1000
800
1000
1800
2.1°C
1.7°C
1.3°C
L Thermocouple -200.0
0.00
0.0
900.0
0.45°C
0.4°C
U Thermocouple -200.0
0.00
0.0
400.0
0.7°C
0.45°C
N Thermocouple -200.0
0.00
0.0
1300.0
1.1°C
0.6°C
mV Read/Source -10.00 75.00 0.015% ± 2
T/C Cable Kit
KIT INCLUDES:
bullet Type J T/C cable
bullet Type T T/C cable
bullet Type K T/C cable
bullet Type E T/C cable
Cable Kit

Ideal for use with MC-1000, PTC-8001 and T120 calibrators. Martel part number 80029.

All cables are terminated with a standard mini-connector on one end and bbare leads on the other.